| 6243 |
SPBRQN001 |
Spring |
SWALIM_WSIS |
07/06/08 |
Bari |
Qandala |
Butiyaalo |
— |
— |
— |
Qandala |
— |
11.4337 |
49.8656 |
71.0 |
— |
— |
— |
— |
Yes |
— |
Yes |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
8.1 |
326.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Improve |
— |
Water Sources Inventory Survey – WSIS |
| 8337 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Oodogooye |
7.0 |
Private |
03/03/18 |
Ugaaso borehole |
— |
8.4864682 |
47.4080974 |
620.0 |
— |
2 |
— |
rural |
yes |
— |
No |
The Generator and the pump are not working due electrical shock to the generator and damage to the pump |
4000 |
5000 |
18 |
3000 |
1 |
— |
330.0 |
pvc |
8.0 |
240.0 |
16.0 |
5.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
40.0 |
Galvanised Steel |
100.0 |
500 |
1 |
1 |
yes |
10 |
8.0 |
Submersible Pump |
Lawara |
8.0 |
90.0 |
Generator |
Perkins |
45.0 |
— |
— |
poor |
The system is not functioning |
no |
— |
— |
— |
— |
— |
— |
Private/Individual |
— |
— |
— |
— |
no |
— |
no |
— |
— |
— |
— |
— |
No intervention since drilled this borehole |
It needs to repair or replace the generator and the pump as well as pipelines |
— |
— |
| 8138 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Gambadha |
1.0 |
Somaliland MoWRD |
07/04/16 |
Gambadha borehole 2 |
— |
8.5715028 |
47.5966741 |
551.0 |
— |
3 |
— |
rural urban |
yes |
— |
Yes |
— |
9000 |
500 |
0 |
1300 |
0.2 |
— |
75.0 |
pvc |
8.0 |
30.0 |
12.0 |
10.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
100.0 |
Galvanised Steel |
1112.0 |
1100 |
8 |
7 |
yes |
6 |
45.0 |
Submersible Pump |
Luara |
11.0 |
45.0 |
Hybrid - Solar/Generator |
Perkins |
45.0 |
WHC SOLAR |
258.0 |
good |
The supply system is working well |
no |
— |
27.0 |
7.4 |
1000.0 |
915.0 |
— |
Communal |
yes |
07/04/16 |
3 |
2 |
no |
— |
no |
— |
— |
— |
— |
— |
— |
Solar 2 damage , generator is heating and pump is old and require to change it. If not immediate intervention is taken the borehole no longer able to supply needed people water
|
— |
— |
| 8111 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Higlo |
1.5 |
Private |
07/04/15 |
Geel caseeye |
— |
8.5646566 |
47.6841849 |
539.0 |
— |
2 |
— |
rural |
yes |
— |
Yes |
— |
0 |
40 |
0 |
0 |
3 |
— |
65.0 |
pvc |
8.0 |
40.0 |
10.0 |
8.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
48.0 |
Galvanised Steel |
100.0 |
0 |
0 |
0 |
yes |
2 |
8.0 |
Submersible Pump |
Luwara |
13.0 |
30.0 |
Solar |
— |
— |
Szyl-p300- 36 |
300.0 |
good |
Two solar panels damaged and need to be changed |
no |
— |
32.0 |
6.8 |
1150.0 |
810.0 |
— |
Communal |
no |
— |
— |
— |
no |
— |
no |
— |
— |
— |
Oxfam GB |
07/04/19 |
Constructed water tank of capacity 48 qubic meter |
Supply system disconnected due to pipes damage and Water cannot go to water tanks. 2 solar panels also not working |
— |
— |
| 7988 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Tukaraq |
0.0 |
Unknown by the operator |
07/04/22 |
Tukarq borehole 1 |
— |
8.5386496 |
47.7905187 |
561.0 |
— |
2 |
— |
rural urban |
yes |
— |
Yes |
— |
23000 |
0 |
0 |
0 |
0 |
— |
30.0 |
pvc |
8.0 |
24.0 |
18.0 |
11.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
80.0 |
Galvanised Steel |
1.0 |
4000 |
6 |
0 |
yes |
5 |
45.0 |
Submersible Pump |
Grounfunds |
7.5 |
24.0 |
Solar |
— |
— |
Photovoltiac monocrystilline |
360.0 |
good |
Several pipelines are connected to the households from the borehole |
no |
— |
32.0 |
6.9 |
1840.0 |
1200.0 |
— |
Communal |
yes |
07/04/20 |
3 |
0 |
no |
— |
no |
— |
— |
— |
ACTED |
01/01/21 |
Wall fence construction and tank pipeline increased and change pump |
Pipelines are damaged specially the lowest once in the borehole. Animal troughs and Bury the pipes from borehole tob entire toen |
— |
— |
| 8014 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Higlo |
3.0 |
Private |
05/10/21 |
Sugule borehole |
— |
8.5868767 |
47.6846015 |
536.0 |
— |
2 |
— |
rural |
yes |
— |
Yes |
— |
0 |
0 |
0 |
0 |
6 |
— |
60.0 |
pvc |
8.0 |
53.0 |
66.0 |
8.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
200.0 |
Galvanised Steel |
600.0 |
0 |
0 |
0 |
no |
— |
— |
Submersible Pump |
Luara |
7.5 |
50.0 |
Solar |
— |
— |
M2 |
200.0 |
good |
This borehole supplies water to large private owned agricultural farm
So it is not open to public and only used for the farm |
no |
— |
31.0 |
7.0 |
1620.0 |
1200.0 |
— |
Private/Individual |
— |
— |
— |
— |
no |
— |
no |
— |
— |
— |
— |
— |
No intervention |
Everything thing is working properly |
— |
— |
| 7989 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Tukaraq |
0.1 |
Chinese government |
07/04/74 |
Tukarq borehole2 |
— |
8.5445533 |
47.7935866 |
538.0 |
— |
2 |
— |
rural urban |
yes |
— |
Yes |
— |
820 |
800 |
0 |
1530 |
0 |
— |
70.0 |
other |
7.0 |
40.0 |
40.0 |
6.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Other |
— |
Galvanised Steel |
300.0 |
200 |
0 |
6 |
yes |
2 |
8.0 |
Surface mounted Pump |
Geounfuds |
7.5 |
— |
Generator |
2 pston |
11.0 |
— |
— |
good |
This an old borehole that it's supply system isnot secure. It is open and and pipelines are are exposure to the sun light |
no |
— |
32.0 |
8.0 |
1830.0 |
1200.0 |
— |
Communal |
no |
— |
— |
— |
no |
— |
no |
— |
— |
— |
— |
— |
Nil |
It requires a protection, big generator and solar system. It also needs solar system |
— |
— |
| 7990 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Gambadha |
1.3 |
Private |
07/04/19 |
Bashiir Borehole |
— |
8.5722509 |
47.5964378 |
543.0 |
— |
3 |
— |
rural |
yes |
— |
Yes |
— |
0 |
0 |
0 |
0 |
2 |
— |
75.0 |
pvc |
8.0 |
30.0 |
12.0 |
2.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Other |
— |
Galvanised Steel |
80.0 |
0 |
0 |
0 |
no |
— |
— |
No Pump |
— |
— |
— |
— |
— |
— |
— |
— |
good |
This is private borehole that is used for watering the agriculture farming only |
no |
— |
32.0 |
7.3 |
1820.0 |
1100.0 |
— |
Private/Individual |
— |
— |
— |
— |
no |
— |
no |
— |
— |
— |
— |
— |
— |
This borehole is private one that is used agricultural only |
— |
— |
| 8740 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Oodogooye |
7.0 |
Somaliland Development Fund-SDF |
07/01/22 |
Oodogooye borehole 1 |
— |
8.4942285 |
47.4203142 |
616.0 |
— |
2 |
— |
rural |
yes |
— |
No |
The borehole is new and not installed the supply system, the pump and the generator all are missing. |
0 |
0 |
0 |
0 |
0 |
— |
310.0 |
other |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Only the borehole drilled by the project. All supply system are not delivered yet. |
no |
— |
— |
— |
— |
— |
— |
Communal |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
All the supply system are missing. The pump, pipelinrs and generator should be connected to the borehole |
— |
— |
| 7981 |
— |
Borehole |
Somaliland MoWRD |
07/04/22 |
Sool |
las_caanood |
Higlo |
3.0 |
Somaliland MoWRD |
07/04/17 |
Higlo borehole |
— |
8.5553756 |
47.7281462 |
544.0 |
— |
1 |
— |
rural urban |
yes |
— |
Yes |
— |
4500 |
17000 |
200 |
40000 |
12 |
— |
65.0 |
pvc |
8.0 |
45.0 |
16.0 |
12.0 |
0.0 |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
16.0 |
Galvanised Steel |
420.0 |
800 |
6 |
2 |
yes |
5 |
8.0 |
Submersible Pump |
Laura |
15.0 |
45.0 |
Hybrid - Solar/Generator |
Adpower |
30.0 |
M2 |
300.0 |
good |
All the system are working |
no |
— |
30.0 |
7.4 |
1900.0 |
1200.0 |
— |
Communal |
no |
— |
— |
— |
no |
— |
no |
— |
— |
— |
Oxfam Novib |
07/04/20 |
Provision of generator construction water tank and extension pf pipelines |
The system is working well and no considerable isssu reported |
— |
— |